Sealed Rechargeable 12v 120ah 200ah 400ah 500ah Lead Acid Batteries For Solar System
|
Still deciding? Get samples of $ !
Request Sample
|
Product Details
| Customization: | Available |
|---|---|
| Type: | Lead-Acid Batteries |
| Usage: | UPS, Electric Power, Lighting |
Secured Trading Service
Diamond Member Since 2020
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Importers and Exporters
Experienced Team
Self-branded
Exhibition Experience
The supplier has import and export rights
The supplier has 28 foreign trading staff(s) and 10 staff(s) with over 6 years of overseas trading experience
The supplier has 2 Self-brands, check the Audit Report for more information
The supplier had participated in offline trade shows, you can check the Audit Report for more information
Sign In to see all verified strength labels (20)
Find Similar Products
Basic Info.
- Nominal Voltage
- 12V
- Discharge Rate
- Low Discharge Rate
- Shape
- Square Battery
- Electrolyte
- Acid
- Installation
- Packaged
- Rechargeable
- Chargeable
- Weight
- 57.9kg ; 62.4kg
- Certificate
- CE; ISO; CNAS; MSDS
- Sealed Type
- Sealed
- Terminal
- F8
- Maintenance Type
- Free
- Max. Discharge Current
- 3000A (5 Sec)
- Transport Package
- Carton and Wooden Box by Sea
- Specification
- 522mm*240mm*219/223mm
- Trademark
- Sunpal
- Origin
- China
- HS Code
- 8507200000
- Production Capacity
- 1000PCS/Per Day
Product Description

Battery Terminal Options
|
Model
|
6-GFM(G)-100Ah
|
6-GFM(G)-150Ah
|
6-GFM(G)-200Ah
|
6-GFM(G)-250Ah
|
|
Cells Per Unit
|
6
|
|||
|
Voltage Per Unit
|
12V
|
|||
|
Capacity
|
100Ah@10hr-rate to 1.80V per cell @25°C
|
150Ah@10hr-rate to 1.80V per cell @25°C
|
200Ah@10hr-rate to 1.80V per cell @25°C
|
250Ah@10hr-rate to 1.80V per cell @25°C
|
|
Weight
|
29kg
|
42kg
|
58.5kg
|
67kg
|
|
Internal Resistance
|
Approx. 6mΩ
|
Approx. 4mΩ
|
Approx. 3.5mΩ
|
Approx. 2.5mΩ
|
|
Terminal
|
F1/F2
|
|||
|
Max. Discharge Current
|
1500A(5s)
|
2250A(5s)
|
3000A(5s)
|
3750A(5s)
|
|
Design Life
|
10~15 years
|
|||
|
Maximum Charging Current
|
25A
|
37.5A
|
50A
|
62.5A
|
|
Float Charging Voltage
|
13.6 V~13.8 V @ 25°C
Temperature Compensation: -20mV/°C/Cell |
|||
|
Cycle Use Voltage
|
14.4 V~14.9 V @ 25°C
Cycle Use Voltage Temperature Compensation: -30mV/°C/Cell |
|||
|
Operating Temperature Range
|
Discharge: -20°C~60°C
Charge: 0°C~50°C Storage: -20°C~60°C |
|||
|
Container Material
|
A.B.S. UL94-HB, UL94-V0 Optional.
|
|||
Advantages:
1. High purity lead-tin alloy, reduce battery self discharge rate and increase battery service life.
2. ABS battery case made by LG raw material to increase battery service life.
3. Heat sealing technique instead of glue sealing to increase the tightness and stability of battery.
4. TTP technique not only reduce internal resistance and material cost but also increase battery life.
5. Conduct four large current discharge texting before package to insure battery quality.
6. Full charge before delivery. Buy and use it directly.
Characteristics Data




1.How long can a battery last?
The service design life of a battery varies considerably with how it is used, how it is maintained and charged, temperature, among other factors.
2.Do I need to add water to my battery?
No. Sealed lead acid batteries do not require the use of water.
3.What determines the life of a VRLA battery?
Sealed lead acid battery life is determined by many factors. These include temperature, depth and rate of discharge, and the number of charges and discharges (called cycles).
4.What is the difference between float and cycle applications?
A float application requires the battery to be on constant charge with an occasional discharge. Cycle applications charge and discharge the battery on a regular basis.
5.What is the definition of "cycle use" and "standby use"?
"Cycle Use" - direct power source: Cycle Use - IT can provide the power supply to power tools, and portable electronic products.It can also be used for cycling charging and discharging usage such as electronics motorbike or vacuum cleaner.
"Standby Use" - back up power: Standby Use is mainly used for emergency power to avoid future damage that may be caused by a sudden power outage.
"Standby Use" - back up power: Standby Use is mainly used for emergency power to avoid future damage that may be caused by a sudden power outage.
6.When should a deep-cycle battery be used?
Deep-cycle batteries are used when 50% or more of the capacity is used per cycle. The most common use of deep-cycle batteries is in applications that require deep, repetitive drain, like powerful car audio systems, trolling motors, golf carts, electric wheelchairs, or RV house power sources. Public safety and high performance vehicles are other applications that call for the special characteristics of deep-cycle batteries.
7.How are batteries rated?
Lead acid batteries are rated based on a capacity given in a defined time. There is not a set industry standard for how to rate a battery.

Send your message to this supplier
People who viewed this also viewed
Product Groups
More
Find Similar Products By Category
- Supplier Homepage
- Products
- Lead Acid Battery
- 12V
- Sealed Rechargeable 12v 120ah 200ah 400ah 500ah Lead Acid Batteries For Solar System
Related Categories
Hot Searches
More