Customization: | Available |
---|---|
After-sales Service: | Free replacement of accessories |
Warranty: | 5 Years |
Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
---|
Payment Methods: |
|
---|---|
Support payments in USD |
Secure payments: | Every payment you make on Made-in-China.com is protected by the platform. |
---|
Refund policy: | Claim a refund if your order doesn't ship, is missing, or arrives with product issues. |
---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Smart Monitoring System
Technical specifications
X3-MIC (THREE PHASE)
|
X3-4.0-T
|
X3-5.0-T
|
X3-6.0-T
|
X3-7.0-T
|
X3-8.0-T
|
X3-9.0-T
|
INPUT (DC)
|
||||||
Max.PV array power [Wp]
|
5200
|
6500
|
7800
|
8400
|
9600
|
10800
|
Max.DC voltage [V]
|
800
|
800
|
800
|
1000
|
1000
|
1000
|
Nominal DC operating voltage [V]
|
600
|
600
|
600
|
600
|
600
|
600
|
Max. input current [A]
|
11/11
|
11/11
|
11/11
|
11/11
|
11/11
|
11/11
|
Max. short circuit current [A]
|
14/14
|
14/14
|
14/14
|
14/14
|
14/14
|
14/14
|
MPPT voltage range[V]
|
160-750
|
160-750
|
160-750
|
160-900
|
160-900
|
160-900
|
Start operating voltage[V]
|
180
|
180
|
180
|
180
|
180
|
180
|
No. of MPP trackers
|
2
|
2
|
2
|
2
|
2
|
2
|
Strings per MPP tracker
|
1
|
1
|
1
|
1
|
1
|
1
|
OUTPUT AC
|
||||||
Nominal AC power [VA]
|
4000
|
5000
|
6000
|
7000
|
8000
|
9000
|
Max. AC power [VA]
|
4000
|
5000
|
6000
|
7000
|
8000
|
9000
|
Nominal grid voltage(AC voltage range) [V]
|
3/N/PE, 3/PE, 230/400(310-480)
|
|||||
Nominal grid frequency/range [Hz]
|
50/60; ±5
|
|||||
Nominal AC current [A]
|
5.8
|
7.2
|
8.7
|
10.1
|
11.6
|
13.0
|
Max. AC current [A]
|
6.4
|
8.0
|
9.6
|
11.2
|
12.8
|
14.4
|
Displacement power factor
|
0.8 leading ~ 0.8 lagging
|
|||||
THDi, rated power [%]
|
<2
|
|||||
EFFICIENCY
|
||||||
MPPT efficiency [%]
|
99.9
|
|||||
Euro efficiency [%]
|
97.8
|
|||||
Max. efficiency [%]
|
98.3
|
|||||
POWER CONSUMPTION
|
||||||
Standby consumption (Night) [W]
|
<3
|
|||||
STANDARD
|
||||||
Over voltage protection
|
YES
|
|||||
Over current protection
|
YES
|
|||||
DC isolation impedance monitoring
|
YES
|
|||||
Ground fault current monitoring
|
YES
|
|||||
DC injection monitoring
|
YES
|
|||||
RCD protection
|
YES
|
|||||
Safety
|
EN62109-1/-2
|
|||||
EMC
|
EN61000-6-1;EN61000-6-2;EN61000-6-3;EN61000-3-2;EN61000-3-3
|
|||||
Certifification
|
AS4777; VDE4105;G98; G99; EN50549; CEI0-21
|
|||||
ENVIRONMENT LIMIT
|
||||||
Degree of protection(according to IEC60529)
|
IP65
|
|||||
Operating temperature range [ºC]
|
-25~+60(derating at 45)
|
|||||
Max. operation altitude [m]
|
2000
|
|||||
Humidity [%]
|
0~100 (condensation)
|
|||||
Storage temperature [ºC]
|
-25~+60
|
|||||
Typical noise emission [dB]
|
<35
|
|||||
DIMENSION AND WEIGHT
|
||||||
Dimensions(WxHxD) [mm]
|
534*419*201
|
|||||
Weight[kg]
|
30
|
|||||
Cooling concept
|
Natural
|
|||||
Topology
|
Non-isolated
|
|||||
Communication interfaces
|
RS485/DRM/Pocket WiFi(optional)/Pocket LAN (optional)/Pocket GPRS (optional)/Meter (optional)/USB-upgrade
|
|||||
LCD display
|
Backlight 20*4 character
|
|||||
Standard warranty [years]
|
5-10
|
X3-MIC (THREE PHASE)
|
X3-10.0-T
|
X3-4.0-S
|
X3-5.0-S
|
INPUT (DC)
|
|
|
|
Max.PV array power [Wp]
|
12000
|
4800
|
6000
|
Max.DC voltage [V]
|
1000
|
1000
|
1000
|
Nominal DC operating voltage [V]
|
600
|
600
|
600
|
Max. input current [A]
|
11/11
|
11
|
11
|
Max. short circuit current [A]
|
14/14
|
14
|
14
|
MPPT voltage range[V]
|
160-900
|
160-900
|
160-900
|
Start operating voltage[V]
|
180
|
180
|
180
|
No. of MPP trackers
|
2
|
1
|
1
|
Strings per MPP tracker
|
1
|
1
|
1
|
OUTPUT AC
|
|||
Nominal AC power [VA]
|
10000
|
4000
|
5000
|
Max. AC power [VA]
|
10000
|
4000
|
5000
|
Nominal grid voltage(AC voltage range) [V]
|
3/N/PE, 3/PE, 230/400(310-480)
|
||
Nominal grid frequency/range [Hz]
|
50/60; ±5
|
||
Nominal AC current [A]
|
14.5
|
5.8
|
7.2
|
Max. AC current [A]
|
16.0
|
6.4
|
8.0
|
Displacement power factor
|
0.8 leading ~ 0.8 lagging
|
||
THDi, rated power [%]
|
<2
|
||
EFFICIENCY
|
|||
MPPT efficiency [%]
|
99.9
|
||
Euro efficiency [%]
|
98
|
||
Max. efficiency [%]
|
98.5
|
||
POWER CONSUMPTION
|
|||
Standby consumption (Night) [W]
|
<3
|
||
STANDARD
|
|||
Over voltage protection
|
YES
|
||
Over current protection
|
YES
|
||
DC isolation impedance monitoring
|
YES
|
||
Ground fault current monitoring
|
YES
|
||
DC injection monitoring
|
YES
|
||
RCD protection
|
YES
|
||
Safety
|
EN62109-1/-2
|
||
EMC
|
EN61000-6-1;EN61000-6-2;EN61000-6-3;EN61000-3-2;EN61000-3-3
|
||
Certifification
|
AS4777; VDE4105;G98; G99; EN50549; CEI0-21
|
||
ENVIRONMENT LIMIT
|
|||
Degree of protection(according to IEC60529)
|
IP65
|
||
Operating temperature range [ºC]
|
-25~+60(derating at 45)
|
||
Max. operation altitude [m]
|
2000
|
||
Humidity [%]
|
0~100 (condensation)
|
||
Storage temperature [ºC]
|
-25~+60
|
||
Typical noise emission [dB]
|
<35
|
||
DIMENSION AND WEIGHT
|
|||
Dimensions(WxHxD) [mm]
|
534*419*201
|
||
Weight[kg]
|
30
|
||
Cooling concept
|
Natural
|
||
Topology
|
Non-isolated
|
||
Communication interfaces
|
RS485/DRM/Pocket WiFi(optional)/Pocket LAN (optional)/Pocket GPRS (optional)/Meter (optional)/USB-upgrade
|
||
LCD display
|
Backlight 20*4 character
|
||
Standard warranty [years]
|
5-10
|
X3-MIC (THREE PHASE)
|
X3-8.0P
|
X3-10.0P
|
X3-12.0P
|
X3-15.0P
|
INPUT (DC)
|
||||
Max.PV array power [Wp]
|
A:3200/B:6400
|
A:4000/B:8000
|
A:4800/B:9600
|
A:6000/B:12000
|
Max.DC voltage [V]
|
1000
|
1000
|
1000
|
1000
|
Nominal DC operating voltage [V]
|
600
|
600
|
600
|
600
|
Max. input current [A]
|
10/20
|
10/20
|
10/20
|
10/20
|
Max. short circuit current [A]
|
12/24
|
12/24
|
12/24
|
12/24
|
MPPT voltage range[V]
|
160-850
|
160-850
|
160-850
|
160-850
|
Start operating voltage[V]
|
180
|
180
|
180
|
180
|
No. of MPP trackers
|
2
|
2
|
2
|
2
|
Strings per MPP tracker
|
A:1/B:2
|
A:1/B:2
|
A:1/B:2
|
A:1/B:2
|
OUTPUT AC
|
||||
Nominal AC power [VA]
|
8000
|
10000
|
12000
|
15000
|
Max. AC power [VA]
|
8000
|
10000
|
12000
|
15000
|
Nominal grid voltage(AC voltage range) [V]
|
3/N/PE, 3/PE, 230/400(310-480)
|
|||
Nominal grid frequency/range [Hz]
|
50/60; ±5
|
|||
Nominal AC current [A]
|
11.6
|
14.5
|
17.4
|
21.7
|
Max. AC current [A]
|
12.8
|
16
|
19.2
|
23.8
|
Displacement power factor
|
0.8 leading ~ 0.8 lagging
|
|||
THDi, rated power [%]
|
<3
|
|||
EFFICIENCY
|
||||
MPPT efficiency [%]
|
99.9
|
|||
Euro efficiency [%]
|
97.8
|
|||
Max. efficiency [%]
|
98.3
|
|||
POWER CONSUMPTION
|
||||
Standby consumption (Night) [W]
|
<3
|
|||
STANDARD
|
||||
Over voltage protection
|
YES
|
|||
Over current protection
|
YES
|
|||
DC isolation impedance monitoring
|
YES
|
|||
Ground fault current monitoring
|
YES
|
|||
DC injection monitoring
|
YES
|
|||
RCD protection
|
YES
|
|||
Safety
|
EN62109-1/-2
|
|||
EMC
|
EN61000-6-1;EN61000-6-2;EN61000-6-3;EN61000-3-12;EN61000-3-11
|
|||
Certifification
|
VDE4105; AS4777; EN50549; IEC61727
|
|||
ENVIRONMENT LIMIT
|
||||
Degree of protection(according to IEC60529)
|
IP65
|
|||
Operating temperature range [ºC]
|
-25~+60(derating at 45)
|
|||
Max. operation altitude [m]
|
2000
|
|||
Humidity [%]
|
0~100 (condensation)
|
|||
Storage temperature [ºC]
|
-25~+60
|
|||
Typical noise emission [dB]
|
<45
|
|||
DIMENSION AND WEIGHT
|
||||
Dimensions(WxHxD) [mm]
|
534*419*179
|
|||
Weight[kg]
|
32
|
|||
Cooling concept
|
Forced-cooling
|
|||
Topology
|
Non-isolated
|
|||
Communication interfaces
|
RS485/DRM/Pocket WiFi(optional)/Pocket LAN (optional)/Pocket GPRS (optional)/Meter (optional)/USB-upgrade
|
|||
LCD display
|
Backlight 16*4 character
|
|||
Standard warranty [years]
|
5/10(optional)
|